ifcx.app / samples

Samples

One house, three ways. Each is a complete model in the editor's native format — open it, change something, and the quantities follow. The figures listed are the model's own, including where a check fails.

Primary — reversing dog-leg stairs

Three storeys on the outer 6.50 × 9.90 m face, four structural slabs and no separate ceilings, dog-leg flights on both lower storeys and a straight flight to the roof. The stairhood plan measures 10.802 m² against a permitted 7.44 m², so it is not a permitted roof element and the measured height reads 10.20 m against the 8.23 m limit — a deliberate, reported failure rather than a hidden one.

  • 41 nodes
  • envelope 64.35 m² ≤ 65.03 m²
  • 16 risers @ 165.625 mm
  • rebar 2,590.20 m / 2,299.616 kg

nteh-village-house.ifcxp · 34,928 bytes · sha256 bc03f237ac596eb6…

Download See the file content

Alternative — straight flight to the roof

The same envelope with a 5.95 × 1.20 m roof void instead of the extended stairhood. The hood plan comes to 7.14 m², inside the 7.44 m² allowance, so it is excluded from the height and the building measures 8.10 m — fully compliant.

  • roof void 7.14 m²
  • hood 7.140 m² ≤ 7.44 m²
  • measured height 8.10 m ≤ 8.23 m

nteh-village-house-alt-straight-roof.ifcxp · 33,467 bytes · sha256 e2e3c6bd4c43afb7…

Download See the file content

Three flat units with a full internal layout

The same envelope divided into three self-contained flats with 100 mm architectural partitions, a door and a window to every room and functional space, and a second stair on the top floor rising to the roof. Rooms came in at 7.85 / 6.90 / 6.91 / 4.25 / 5.17 / 14.10 m² against targets of 8 / 8 / 8 / 4 / 6 / 15 — the walled stair enclosure costs 10.03 m², and the shortfall is reported rather than smoothed.

  • 155 nodes
  • 44 walls · 23 doors · 18 windows
  • internal walls 100 mm
  • scheduled 45.18 m² of 58.73 m² plate

nteh-village-house-3flats.ifcxp · 98,679 bytes · sha256 dca2306ddad8be5f…

Download See the file content
About the failures. The primary variant reports a measured height of 10.20 m against an 8.23 m limit. That is not a defect in the sample — it is the compliance check doing its job on a roof element that outgrew its allowance, kept in the model so the check stays visibly able to say no.

Read the file, not just the picture

The proof page takes one wall from the three-flat model and shows it twice: selected in the editor, and as the node sitting in the saved file. Same identifier in both places.